ICL Sizing Calculator
ICL Fit is a Pentacam-based AI agent for ICL sizing. Import a standard Pentacam scan and it recommends the best-fit EVO or EVO+ ICL size for that eye.
What is the ICL Fit sizing calculator?
ICL Fit is an AI ICL sizing calculator for EVO and EVO+ Implantable Collamer Lens surgery. It reads the anterior-segment measurements from a standard Pentacam scan and recommends which of the four ICL lengths, 12.1 mm, 12.6 mm, 13.2 mm or 13.7 mm, is the best fit for the individual eye. It is built by Gurpal Virdi, MD and Matt Hirabayashi, MD, refractive surgeons and authors of peer-reviewed ICL sizing research.
How does the calculator work?
- Take the Pentacam scan you already take. No extra imaging step is added to the refractive workup.
- Import the Pentacam export into ICL Fit. The calculator reads the measurements directly, so nothing is typed in by hand.
- Get the best-fit size. The AI agent weighs the eye’s anterior-segment anatomy as a whole and recommends the ICL length most likely to fit that eye.
- Decide as the surgeon. The recommendation informs the sizing decision. It does not replace clinical judgment.
How does it compare with other ICL sizing calculators?
ICL sizing calculators differ mainly in what they measure and what a clinic has to own to use them.
| Calculator or method | What it sizes from | What the clinic needs |
|---|---|---|
| STAAR OCOS (manufacturer calculator) | White-to-white and anterior chamber depth | Nothing beyond a standard workup |
| Biometer-adjusted white-to-white nomograms | White-to-white and anterior chamber depth, corrected for the measuring device | Nothing beyond a standard workup |
| KS, NK and LASSO formulas | Anterior-segment OCT measurements such as angle-to-angle distance and crystalline lens rise | Anterior-segment OCT |
| Reinstein formula | Very-high-frequency digital ultrasound measurements behind the iris | Very-high-frequency digital ultrasound |
| UBM-based AI, such as ICL Guru | Ultrasound biomicroscopy images | UBM and an operator trained to acquire reproducible images |
| ICL Fit | The anterior-segment measurements in a standard Pentacam scan, learned against real surgical outcomes | Nothing beyond the Pentacam |
A longer comparison is in ICL sizing calculators and formulas compared.
Why size for best fit instead of a vault number?
Vault, the clearance between the ICL and the natural crystalline lens, is often treated as a single target figure. It is not fixed. Our study of ICL vault and anterior chamber angle under varying lighting conditions measured vault shifting within the same eye as lighting changed, and it also moves with accommodation and over the years after surgery. ICL Fit therefore recommends the size that best fits the eye as a whole, rather than sizing to one vault number.
Is there an AI calculator for ICL sizing?
Yes. ICL Fit is a Pentacam-based AI agent for ICL sizing. A surgeon imports the export from a standard Pentacam scan and ICL Fit recommends the best-fit EVO or EVO+ ICL size for that eye, choosing among the four available lengths: 12.1 mm, 12.6 mm, 13.2 mm and 13.7 mm.
Can you size an ICL from a Pentacam scan alone?
Yes. ICL Fit sizes from the anterior-segment measurements a Pentacam already reports, covering anterior chamber depth and volume, corneal curvature and the other parameters that describe the space the lens has to occupy. It does not require ultrasound biomicroscopy or any hardware beyond the Pentacam.
Does ICL Fit need UBM or OCT images?
No. ICL Fit works from numeric measurements rather than from images. The team's earlier VAULT and VAULT-OCT research was image-based and both studies are published. The product moved to measurements deliberately, so that sizing does not depend on hardware most refractive practices do not own or on the quality of an individual image capture.
Does ICL Fit size to a target vault number?
No. ICL Fit recommends the best-fit lens size for the individual eye. Vault is dynamic: it changes with lighting and pupil size, with accommodation, and over the years after surgery, so a single vault figure is a snapshot of how a lens fits rather than a fixed property of the eye.
How is ICL Fit different from the STAAR OCOS calculator?
The STAAR OCOS calculator sizes primarily from white-to-white and anterior chamber depth. ICL Fit draws on the fuller set of anterior-segment measurements in a Pentacam scan and learns from real surgical outcomes rather than applying a fixed formula. ICL Fit addresses lens size. Lens power is still calculated and ordered through the manufacturer's calculator.
Who can use the ICL Fit sizing calculator?
ICL Fit is clinical decision-support software for ophthalmologists and refractive surgeons performing EVO ICL surgery. Access is by account, and surgeons can join the waitlist at icl.fit. It informs the surgeon's sizing judgment and does not replace it, and it is not patient-facing medical advice.
Research behind the calculator
The ICL Fit team has published on ICL sizing, fit and outcomes, including the VAULT and VAULT-OCT studies in the Journal of Cataract & Refractive Surgery and a series on ICL exchanges and explants due to sizing. The full list is on the publications page. See also the ICL sizing FAQ and the ICL education notes.